Corrigendum to Commission Directive (EU) 2016/844 of 27 May 2016 amending Directive 2009/45/EC of the European Parliament and of the Council on safety rules and standards for passenger ships (OJ L 141, 28.5.2016)

On page 55, in Table 5.1(a) in paragraph (2), subparagraph (h) of the Annex, concerning the Annex to Directive 2009/45/EC:
for:
‘Table 5.1(a)
Fire integrity of bulkheads separating adjacent spaces
Spaces
(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)
Control stations
(1)
A-0e
A-0
60
A-0
A-15
A-60
A-15
A-60
A-60
*
A-60
Corridors
(2)
Ce
B-0e
A-0e
B-0e
B-0e
A-60
A-15
A-60
A-15
A-0d
*
A-30
Accommodation spaces
(3)
Ce
A-0e
B-0e
B-0e
A-60
A-0
A-0
A-15
A-0d
*
A-30
A-0d
Stairways
(4)
A-0e
B-0e
A-0e
B-0e
A-60
A-0
A-0
A-15
A-0d
*
A-30
Service spaces (low risk)
(5)
Ce
A-60
A-0
A-0
A-0
*
A-0
Machinery spaces of category A
(6)
*
A-0
A-0
A-60
*
A-60
Other machinery spaces
(7)
A-0b
A-0
A-0
*
A-0
Cargo spaces
(8)
*
A-0
*
A-0
Service spaces (high risk)
(9)
A-0b
*
A-30
Open decks
(10)
A-0
Special category and Ro-Ro spaces
(11)
A-30’
read:
‘Table 5.1(a)
Fire integrity of bulkheads separating adjacent spaces
Spaces
(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)
Control stations
(1)
A-0c
A-0
A-60
A-0
A-15
A-60
A-15
A-60
A-60
*
A-60
Corridors
(2)
Ce
B-0e
A-0a
B-0e
B-0e
A-60
A-0
A-0
A-15
A-0d
*
A-30
Accommodation spaces
(3)
Ce
A-0a
B-0e
B-0e
A-60
A-0
A-0
A-15
A-0d
*
A-30
A-0d
Stairways
(4)
A-0a
B-0e
A-0a
B-0e
A-60
A-0
A-0
A-15
A-0d
*
A-30
Service spaces (low risk)
(5)
Ce
A-60
A-0
A-0
A-0
*
A-0
Machinery spaces of category A
(6)
*
A-0
A-0
A-60
*
A-60
Other machinery spaces
(7)
A-0b
A-0
A-0
*
A-0
Cargo spaces
(8)
*
A-0
*
A-0
Service spaces (high risk)
(9)
A-0b
*
A-30
Open decks
(10)
A-0
Special category spaces
(11)
A-30’
on page 56, in Table 5.2(a) in paragraph (2), subparagraph (i) of the Annex, concerning the Annex to Directive 2009/45/EC:
for:
‘Table 5.2(a)
Fire integrity of decks separating adjacent spaces
Spaces Below↓Spaces → Above(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)
Control stations
(1)
A-0
A-0
A-0
A-0
A-0
A-60
A-0
A-0
A-0
*
A-60
Corridors
(2)
A-0
*
*
A-0
*
A-60
A-0
A-0
A-0
*
A-30
Accommodation spaces
(3)
A-60
A-0
*
A-0
*
A-60
A-0
A-0
A-0
*
A-30
A-0d
Stairways
(4)
A-0
A-0
A-0
*
A-0
A-60
A-0
A-0
A-0
*
A-30
Service spaces (low risk)
(5)
A-15
A-0
A-0
A-0
*
A-60
A-0
A-0
A-0
*
A-0
Machinery spaces of category A
(6)
A-60
A-60
A-60
A-60
A-60
*
A-60f
A-30
A-60
*
A-60
Other machinery spaces
(7)
A-15
A-0
A-0
A-0
A-0
A-0
*
A-0
A-0
*
A-0
Cargo spaces
(8)
A-60
A-0
A-0
A-0
A-0
A-0
A-0
*
A-0
*
A-0
Service spaces (high risk)
(9)
A-60
A-30
A-0d
A-30
A-0d
A-30
A-0d
A-0
A-60
A-0
A-0
A-0
*
A-30
Open decks
(10)
*
*
*
*
*
*
*
*
*
A-0
Special category and Ro-Ro spaces
(11)
A-60
A-30
A-30
A-0d
A-30
A-0
A-60
A-0
A-0
A-30
A-0
A-30’
read:
‘Table 5.2(a)
Fire integrity of decks separating adjacent spaces
Space BelowSpace Above (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
Control stations
(1)
A-0
A-0
A-0
A-0
A-0
A-60
A-0
A-0
A-0
*
A-60
Corridors
(2)
A-0
*
*
A-0
*
A-60
A-0
A-0
A-0
*
A-30
Accommodation spaces
(3)
A-60
A-0
*
A-0
*
A-60
A-0
A-0
A-0
*
A-30
A-0d
Stairways
(4)
A-0
A-0
A-0
*
A-0
A-60
A-0
A-0
A-0
*
A-30
Service spaces (low risk)
(5)
A-15
A-0
A-0
A-0
*
A-60
A-0
A-0
A-0
*
A-0
Machinery spaces of category A
(6)
A-60
A-60
A-60
A-60
A-60
*
A-60f
A-30
A-60
*
A-60
Other machinery spaces
(7)
A-15
A-0
A-0
A-0
A-0
A-0
*
A-0
A-0
*
A-0
Cargo spaces
(8)
A-60
A-0
A-0
A-0
A-0
A-0
A-0
*
A-0
*
A-0
Service spaces (high risk)
(9)
A-60
A-30
A-0d
A-30
A-0d
A-30
A-0d
A-0
A-60
A-0
A-0
A-0
*
A-30
Open decks
(10)
*
*
*
*
*
*
*
*
*
A-0
Special category spaces
(11)
A-60
A-30
A-30
A-0d
A-30
A-0
A-60
A-0
A-0
A-30
A-0
A-30’
on page 61, in paragraph (2)(l) of the Annex, concerning point 7 of the rule 9a in Annex I to Directive 2009/45/EC:
for:

‘.7 Ventilation systems for laundries in passenger ships carrying more than 36 passengers

Exhaust ducts from laundries and drying rooms of category (13) spaces as defined in Regulation II-2/B//.2.2 shall be fitted with:’,
read:

‘.7 Ventilation systems for laundries in passenger ships carrying more than 36 passengers

Exhaust ducts from laundries and drying rooms of category (13) spaces as defined in Regulation II-2/B/4.2.2 shall be fitted with:’.
Share document:

Top documents

About EuroDocs

The legislative database of European documents. In European Union law, a decision is a legal instrument which is binding upon those individuals to which it is addressed. Regulations specifically means a piece of delegated legislation drafted by subject matter experts to enforce a statutory instrument.